電気特性電気特性電気特性140型(5)RAS-AP140TG容量・型名(相当馬力)室外ユニット型式電源仕様定格冷房標準能力(kW)定格暖房標準能力(kW)最大暖房低温能力(kW)外形寸法W×D×H(mm)製品質量(kg)外装色(マンセル記号)運転音[dB(A)]冷房(kW)消費電力暖房(kW)冷房(A)運転電流暖房(A)力率冷房(%)暖房(%)始動電流(A)560型(20)615型(22)670型(24)730型(26)775型(28)850型(30)900型(32)950型(34)1000型(36)RAS-AP560TGRAS-AP615TGRAS-AP670TGRAS-AP730TGRAS-AP775TGRAS-AP850TGRAS-AP900TGRAS-AP950TGRAS-AP1000TGRAS-AP280TGRAS-AP335TGRAS-AP335TGRAS-AP450TGRAS-AP450TGRAS-AP500TGRAS-AP500TGRAS-AP500TGRAS-AP500TGRAS-AP280TGRAS-AP280TGRAS-AP335TGRAS-AP280TGRAS-AP335TGRAS-AP335TGRAS-AP400TGRAS-AP450TGRAS-AP500TG容量・型名(相当馬力)室外ユニット型式構成室外ユニット電源仕様定格冷房標準能力(kW)定格暖房標準能力(kW)最大暖房低温能力(kW)外形寸法W×D×H(mm)製品質量(kg)外装色(マンセル記号)運転音[dB(A)]56.063.053.6258×2冷房(kW)消費電力暖房(kW)冷房(A)運転電流暖房(A)力率冷房(%)暖房(%)始動電流(A)(6.92)×2(8.35)+(6.92)(8.35)×2(5.16×2)+(6.92)(5.16×2)+(8.35)(6.04×2)+(8.35)(6.04×2)+(10.6)(6.04×2)+(5.16×2)(6.04×2)×2219×2電動機出力(kW)(0.24×2)×2(0.24×2)+(0.24×2)(0.24×2)×2(0.46×2)+(0.24×2)(0.46×2)+(0.24×2)(0.52×2)+(0.24×2)(0.52×2)+(0.35×2)(0.52×2)+(0.46×2)(0.52×2)×2ガス(mm)φ28.58φ15.88液(mm)容量・型名(相当馬力)1060型(38)1120型(40)1180型(42)1220型(44)1280型(46)1360型(48)1400型(50)1450型(52)1500型(54)RAS-AP1060TGRAS-AP1120TGRAS-AP1180TGRAS-AP1220TGRAS-AP1280TGRAS-AP1360TGRAS-AP1400TGRAS-AP1450TGRAS-AP1500TGRAS-AP400TGRAS-AP400TGRAS-AP400TGRAS-AP500TGRAS-AP500TGRAS-AP500TGRAS-AP500TGRAS-AP500TGRAS-AP500TGRAS-AP335TGRAS-AP400TGRAS-AP400TGRAS-AP400TGRAS-AP400TGRAS-AP450TGRAS-AP500TGRAS-AP500TGRAS-AP500TGRAS-AP335TGRAS-AP335TGRAS-AP400TGRAS-AP335TGRAS-AP400TGRAS-AP400TGRAS-AP400TGRAS-AP450TGRAS-AP500TG室外ユニット型式構成室外ユニット電源仕様定格冷房標準能力(kW)定格暖房標準能力(kW)最大暖房低温能力(kW)外形寸法W×D×H(mm)製品質量(kg)外装色(マンセル記号)運転音[dB(A)]10611895.8263+263×2冷房(kW)消費電力暖房(kW)冷房(A)運転電流暖房(A)力率冷房(%)暖房(%)始動電流(A)定格風量(m3/min)256+219×2(0.35×2)+ 電動機出力(kW)(0.24×2)×2送風機主配管サイズガス(mm)液(mm)φ38.1φ19.05160型(6)RAS-AP160TG14.016.013.016.018.015.0950×765×1,755194753.193.0210.29.79090−6.02.681540.19φ15.88φ9.52793.743.5912.011.59090−6.13.111750.26φ19.05φ9.5261.569.056.867.077.560.02,440×765×1,755263+258263×28517.816.655.952.19292−6.58619.319.060.659.69292−6.58416.215.550.848.69292−6.4219+219219×2φ28.58φ15.88φ28.58φ15.88112125101118132107263×33,670×765×1,755263×2+2639033.430.9104.897.09292−6.39135.733.3112.0104.58931.028.497.389.19292−6.49292−6.2×2(10.6)×2+(8.35)(10.6)×3256×3256×2+219(0.35×2)×2+ (0.24×2)(0.35×2)×3φ38.1φ19.05φ38.1φ19.05224型(8)RAS-AP224TG280型(10)RAS-AP280TG三相200V22.425.022.828.031.526.81,210×765×1,755258ナチュラルグレー(1.0Y 8.5/0.5)785.695.5217.917.39292−6.64.86185818.087.7325.424.39292−6.46.922190.16×2φ19.05φ9.520.24×2φ22.2φ9.52三相200V73.082.572.4356+258356+263ナチュラルグレー(1.0Y 8.5/0.5)8824.724.077.575.39292−6.58721.521.967.568.79292−6.58620.520.164.363.19292−6.5346+219346+219φ31.75φ19.05φ31.75φ19.05三相200V1221281401451131194,060×765×1,755356+263+263356+263×2356+356+263356×2+263ナチュラルグレー(1.0Y 8.5/0.5)9039.537.3123.9117.09137.737.1118.3116.49035.335.7110.8112.09292−6.49292−6.3(6.04×2)+ (10.6)×2(6.04×2)+ (10.6)+(8.35)+(10.6)362+256+219362+256×2362+346+256362×2+256(0.52×2)×2+ (0.52×2)+ (0.35×2)×2(0.52×2)+ (0.35×2)+(0.24×2)φ38.1φ19.05φ38.1φ19.05335型(12)RAS-AP335TG400型(14)RAS-AP400TG33.537.530.040.045.035.8263839.648.8630.227.89292−6.58.352198612.311.638.636.49292−6.210.62560.35×2φ25.4φ12.70.24×2φ25.4φ12.785.077.595.090.075.678.02,830×765×1,75590.010083.8356+263356+2638926.525.583.280.09292−6.3362+219362+256φ31.75φ19.05φ31.75φ19.051361401501551291314,450×765×1,7559140.739.4127.7123.69292−6.49292−6.3(6.04×2)+ (6.04×2)×2 (5.16×2)+(10.6)(0.52×2)+(0.46×2) +(0.35×2)φ38.1φ19.05(0.35×2)φ38.1φ19.0526高効率TGシリーズ )APF2015(通年エネルギー消費効率)圧縮機電動機出力(kW)送風機定格風量(m3/min)電動機出力(kW)ガス(mm)主配管サイズ液(mm)(冷暖切換システム)APF2015(通年エネルギー消費効率)圧縮機電動機出力(kW)送風機定格風量(m3/min)主配管サイズ(冷暖切換システム)APF2015(通年エネルギー消費効率)圧縮機電動機出力(kW)(10.6)+(8.35)(冷暖切換システム)(注1) 各性能はJIS B 8616:2015およびJRA 4002:2016条件(定格冷房標準時:室内側27℃DB/19℃WB 室外側35℃DB、定格暖房標準時:室内側20℃DB 室外側7℃DB/6℃WB最大暖房低温時:室内側20℃DB (注2) 電気特性は室外ユニット単体の値です。(注3) 運転音はJIS B 8616:2015およびJRA 4002:2016に基づいた音響パワーレベルの値です。(注4) 電気特性の運転電流欄の「冷房」または「暖房」の電流値が20Aを超える空調機は、「高圧又は特別高圧で受電する需要家の高調波抑制対策ガイドライン」対象機器となります。 (注5) APF2015の値は、JIS B 8616:2015およびJRA 4002:2016に基づいた値です。(注6) 構成室外ユニットの組み合わせは表中の組み合わせ以外はできません。(注7) 560型以上の組み合わせユニットの幅寸法は、室外ユニット間の隙間が20mmの場合の値です。 室外側2℃DB/1℃WB)で配管長7.5m(140〜500型)、10.0m(560〜850型)、12.5m(1000〜1220型)、15m(1280〜1500型)、高低差0m、室内ユニット(てんかせ4方向)を100%接続した場合の値です。回路種別番号・換算係数は機種により異なりますので、弊社営業窓口までお問い合わせください。ただし、オプションの「防雪フード」「吸込網(右側面用・左側面用)」を取り付ける場合には50mm以上、「吹出ダクトキット」を取り付ける場合には60mm以上必要です。(50/60Hz)450型(16)RAS-AP450TG500型(18)RAS-AP500TG45.050.045.650.056.048.01,600×765×1,7553568412.411.838.937.09292−6.58614.214.444.645.29292−6.45.16×26.04×23463620.46×2φ28.58φ12.70.52×2φ28.58φ15.8810095.011210693.696.03,220×765×1,755356+356356×28826.626.283.582.29292−6.58928.428.889.190.49292−6.4362+346362×2φ31.75φ19.05φ38.1φ19.051451501601651411444,840×765×1,755356×2+356356×39040.839.6128.0124.39142.641.7133.7130.89292−6.49292−6.4(6.04×2)×2 +(5.16×2)(6.04×2)×3362×2+346(0.52×2)×2+ (0.46×2)(0.52×2)×3362×3φ38.1φ19.05φ38.1φ19.05 ■標準仕様表(フレックスマルチ 冷暖切換型
元のページ ../index.html#27