―――――――――――――――――――――――――――38――――――――――――37―――42―――40―――換気関連機器295KPI-AP252S1単相200V普通換気全熱交換気強風0.72/0.77141/15425075/11574696828.5/3040/41弱風0.55/0.5962/74150/14527/3879.5/8074.5/7573/73.521.5/20.524.5/25微風0.2651強風0.71/0.76140/15225075/115―――120/10516/2182/8377/78.575.5/7720/21.522.5/23.529.5/3140/411.3以下/1.2以下不織布フィルター(質量法捕集効率82%)−10℃〜40℃ 相対湿度80%以下23単相200V普通換気強風弱風微風0.4895(急風)1.95/2.70390/515650160/2251.21/1.51238/294500120/1501.15/1.27133/157325/31051/58235/20527/2535.5/3648.5/47.525/2636.5/33.523.5/2227/24.5不織布フィルター(質量法捕集効率82%)−10℃〜40℃ 相対湿度80%以下単相200V普通換気強風弱風微風0.90170370/32028/21(急風)2.75/3.40525/6651,000150/2002.20/2.75425/545800130―――2.30/2.60295/360580/59068/7136/35.552/5130/2946/4422/21.530/2736.5/3754/53.5不織布フィルター(質量法捕集効率82%)−10℃〜40℃ 相対湿度80%以下単相200V普通換気強風微風(急風)5.60/6.801,060/1,3302,000135/185弱風4.45/5.35850/1,0601,500135/1851.95/1.90360/355700/57029/27―――24/2333/304.65/5.15560/7101,05066/91―――3042/4440/39.556/55.554.5/53不織布フィルター(質量法捕集効率82%)−10℃〜40℃ 相対湿度80%以下※2.※3.(注1)電流、消費電力、効率は上記風量時の値です。(注2)本体吹出口運転音は斜め45゜、1.5m前方の値となります。(注3)手動で普通換気に設定した場合でも結露防止のため、外気相対湿度が80%以上または外気が8℃以下では自動的に「全熱交換器」となります。(この場合、リモコンの表示は「普通換気」のままです。)(注4)自動換気切換機能付きです。(注5)予熱時外気取り入れ停止制御付きです。全熱交換器用リモコン(PC-MLK)を標準設定でご使用の場合には、「強風」「弱風」「微風」の3段階の風量切替です。「急風」でご使用の場合には、本体のディップスイッチで設定を変更するか、全熱交換器用リモコンで設定を変更する必要があります。(その場合の全熱交換器用リモコンの画面表示は「強風」表示になります。)「エンタルピー交換効率」は、JIS B 8628に規定されている表示値規格に基づく値で、給気と排気の風量比や空気条件により変動します。−10℃以下は寒冷地運転モード(給気用送風機のみ間欠運転60分運転、10分停止)で運転します。外気(OA)が−15℃以下ではご使用になれません。給気用送風機のみ停止する場合があります。強風0.54/0.64108/12615075/12074696826.5/2935.5/38暖房時冷房時本体直下1.5m本体吹出口運転音〔dB(A)〕起動電流(A)フィルター材質 本体設置空気条件給気および排気空気条件質量(kg)製品型式電源換気方式風量設定※1電流(A)消費電力(W)風量(m3/h)機外静圧(Pa)温度交換効率(%)エンタルピー交換効率(%)※2(急風)1.27/1.59250/310500140/2107468.568暖房時冷房時本体直下1.5m本体吹出口35.5/3649.5運転音〔dB(A)〕起動電流(A)フィルター材質 本体設置空気条件給気および排気空気条件質量(kg)製品型式電源換気方式風量設定※1電流(A)消費電力(W)風量(m3/h)機外静圧(Pa)温度交換効率(%)エンタルピー交換効率(%)※2(急風)2.20/2.75420/540800150/23075717035.554/53.5暖房時冷房時本体直下1.5m本体吹出口運転音〔dB(A)〕起動電流(A)フィルター材質 本体設置空気条件給気および排気空気条件質量(kg)製品型式電源換気方式風量設定※1電流(A)消費電力(W)風量(m3/h)機外静圧(Pa)温度交換効率(%)エンタルピー交換効率(%)※2(急風)4.40/5.40840/1,0701,500150/25075.571.570.539.555暖房時冷房時本体直下1.5m本体吹出口運転音〔dB(A)〕起動電流(A)フィルター材質 本体設置空気条件給気および排気空気条件質量(kg)※1.全熱交換気普通換気強風0.54/0.64108/12615075/120―――弱風0.39/0.4445/52105/9536/4878/7973/7471.5/7220.5/2026/25微風0.19/0.2138/4190/7527/3079.5/8174.5/76.573/7519.5/1922.5/22弱風0.39/0.4445/52105/9536/48―――微風0.19/0.2138/4190/7527/30―――27/29.535.5/38.520.5/2026/2519.5/1923/220.9以下−15℃※3〜40℃ 相対湿度80%以下。ただし、外気は一般外気条件、還気は一般居室空調温湿度条件22KPI-AP502S1微風0.4895(急風)1.28/1.60252/312500140/210全熱交換気弱風強風1.21/1.50238/292500120/1501.15/1.27133/156325/31051/5878.5/7972.5/7372/72.524/2536.5/33.5235/20527/2581/82.5―76/77.5―75/76.5―24/22.53727/24.549.52.7以下/2.5以下7468.5683448.5/47.5−15℃※3〜40℃ 相対湿度80%以下。ただし、外気は一般外気条件、還気は一般居室空調温湿度条件36KPI-AP802S1全熱交換気強風弱風(急風)2.25/2.80435/550800150/230微風0.90170370/32028/2182.5/8479/8178/8022/21.530/2754/53.55.7以下/5.1以下2.15/2.70415/5358001307571702.25/2.60295/360580/59068/717873.572.529/2846/4434.5/33.552/51−15℃※3〜40℃ 相対湿度80%以下。ただし、外気は一般外気条件、還気は一般居室空調温湿度条件58KPI-AP1502S1全熱交換気弱風強風微風(急風)4.60/5.50880/1,1001,500150/2504.30/5.25820/1,0301,500135/18575.571.570.538.5/3954/534.60/5.15560/7101,05066/9179.574.573.53042/441.95/1.90360/355700/57029/2783/84.580/81.579/80.524/2333/3041.5/4156/5511.3以下/10.1以下−15℃※3〜40℃ 相対湿度80%以下。ただし、外気は一般外気条件、還気は一般居室空調温湿度条件120全熱交換気強風弱風0.86/1.040.84/0.9291/111171/208215350421108075767170752941/39弱風0.55/0.5962/74150/14527/38―――22/2124/25微風0.2651(急風)0.96/1.13190/225350145/200120/10516/21―――75717031/32.54420/21.523.5/2121.5/20.526.5/272.1以下/1.9以下KPI-AP652S1全熱交換気弱風強風微風0.70140300/26029/2681/8276.5/7875/77221.70/2.25340/435650135/1601.85/2.15235/265510/48083/8775.5/7670.5/71.569/7029.5/2943.5/437368.567.537/38.553/557368.567.534.5/35.55148KPI-AP1002S1全熱交換気強風弱風微風1.05195420/37521/1783/8479/8177.5/79.523/2239/39.533/30.554/53.56.2以下/5.9以下2.70/3.25515/6351,000125/1202.55/2.75425/475820/78080/7277/7872.5/73.571.5/7231.575717075717035.553/51.547.5/46.564KPI-AP2002S1全熱交換気強風弱風微風5.40/6.601,030/1,2802,0001057571703955/545.25/5.75870/1,0001,650/1,5802.15/2.10400/385820/71018/1383.5/85.580/8379/8224/2334/3271/6677/7872.5/7371.5/7235/34.549/4875717012.3以下/11.7以下13250/60HzKPI-AP352S1普通換気弱風強風0.89/1.060.84/0.9391/111176/21121535042110――――――微風0.34/0.3366/65145/13019/1583/8479.5/80.579/801819.5/19(急風)0.99/1.17195/232350145/200微風0.34/0.3366/65145/13019/15―――1819.5/1932/33.54430/29.541/39.521.5/20.526.5/273250/60Hz普通換気(急風)1.95/2.70390/520650160/225強風弱風微風0.70140300/26029/261.70/2.25340/435650135/1601.85/2.15235/265510/48083/8736.5/37.531.5/3143.5/4323/2231.5/3038/39.553/5531.5/304.8以下/4.5以下5150/60Hz普通換気(急風)2.70/3.35515/6601,000150/200強風弱風微風1.05195420/37521/17―――23/2233/30.52.65/3.25510/6301,000125/1202.55/2.80425/475820/78080/72―――34/3347.5/46.553/51.550/60Hz普通換気(急風)5.55/6.751,060/1,3302,000135/185強風弱風微風5.35/6.601,025/1,2802,000105―――4155/545.25/5.75870/1,0051,650/158071/66―――2.15/2.10400/385820/71018/13―――36.5/3649/4824.5/23.534/3256/55.5■ 仕様表(てんうめ型 単相200V)製品型式KPI-AP152S1電源換気方式風量設定※1電流(A)消費電力(W)風量(m3/h)機外静圧(Pa)温度交換効率(%)エンタルピー交換効率(%)※2全熱交換器てんうめ型・てんかせ型てんうめ型・てんかせ型
元のページ ../index.html#296