費電力水流量水圧損失冷却能力費電力水流量水圧損失冷却能力費電力水流量水圧損失冷却能力水容357912152025357912152025357912152025357912152025357912152025357912152025冷水出口温度冷水入口温度710121417202530710121417202530710121417202530710121417202530710121417202530710121417202530周囲空気乾球温度−7.468.108.729.6710.6111.2111.82℃℃℃流流小大m3/hm3/hm3MPa12注) 内は標準運転条件を示します。(℃)(℃)(℃)型式項目・単位吸込空気乾球温度冷水出口温度冷水入口温度最量最量最小保有水量許圧注(1)注(2)152025303540最小保有水量は、圧縮機の発停頻度を基準内に収めるために必要な最低限の水量であり、水温制御を安定させるための必要水量ではありませんのでご注意ください。最小流量は実際に使用される冷水出口温度により異なります。( )内の値は、冷却運転の冷水出口温度を5℃未満でご使用になる場合の最小流量です。最小保有水量は、復帰温度差2℃設定時の場合です。設定変更をした場合、必要な保有水量が変わりますのでご注意ください。RCUNP250AV1冷消(kW)(m3/h)(kW)26.528.330.131.934.737.439.240.925.527.329.231.033.736.538.240.024.226.027.829.732.435.236.938.722.824.626.528.331.033.835.537.321.323.225.026.829.632.334.135.819.921.723.525.428.130.832.634.42.0(4.3)10.60.105.45.45.45.45.45.45.45.46.16.16.16.26.26.26.26.36.86.86.96.96.97.07.17.17.57.67.67.77.77.87.98.08.38.38.48.48.58.68.78.99.29.39.39.49.59.69.79.95.704.875.185.495.976.436.747.035.484.705.025.335.806.286.576.885.204.474.785.115.576.056.356.664.904.234.564.875.335.816.116.424.583.994.304.615.095.565.876.16−3.734.044.374.835.305.615.92RCUNP250AV1RCUNP375AV1冷消(kPa)80.260.067.274.887.3100.0109.0117.874.656.263.570.982.895.8104.0113.267.751.358.065.676.889.497.7106.760.746.353.260.070.983.091.199.753.641.647.854.365.176.684.692.4−36.842.649.259.170.177.885.9(kW)39.742.445.247.952.056.158.861.438.341.043.846.550.654.757.460.036.339.041.844.548.652.755.458.034.237.039.742.446.650.753.355.932.034.837.540.244.348.551.153.729.832.635.338.042.146.348.951.5(kW)15〜433〜2533以下3.0(6.5)7.87.87.87.87.87.87.87.88.88.88.98.98.98.99.09.19.89.89.99.910.010.110.210.310.810.911.011.011.111.211.411.512.012.012.112.212.312.412.612.813.213.313.413.513.713.814.014.3RCUNP375AV1(m3/h)(kPa)29.822.225.027.932.537.540.944.427.820.823.626.430.935.839.142.525.219.021.624.328.733.336.639.922.517.219.622.226.531.034.137.219.915.417.620.124.128.531.534.6−13.615.718.121.926.129.032.0(kW)52.956.660.263.969.474.978.481.951.054.758.362.067.572.976.580.048.452.055.759.364.870.373.877.345.649.352.956.662.167.671.174.642.746.350.053.759.164.668.171.739.843.447.150.756.261.765.268.714.00.131.0以下8.547.297.778.248.949.6510.1110.568.237.057.538.008.709.419.8710.327.806.717.197.658.369.069.539.987.356.366.837.298.028.729.179.616.885.996.456.917.628.348.799.24−5.616.076.547.247.968.418.86RCUNP500AV1冷消(kW)10.810.810.810.810.810.810.810.812.212.312.312.312.412.412.512.613.613.613.713.813.914.014.114.315.015.115.215.315.415.615.816.016.616.716.816.917.117.217.517.718.418.518.618.819.019.219.519.8(m3/h)11.379.7410.3510.9911.9412.8813.4814.0910.979.4110.0310.6611.6112.5413.1613.7610.418.949.5810.2011.1512.0912.6913.309.808.489.109.7410.6811.6312.2312.839.187.968.609.2410.1711.1111.7112.33(kPa)78.659.066.073.886.199.2107.9117.273.655.362.369.881.894.4103.2112.266.750.357.264.375.888.296.5105.359.645.652.059.070.082.090.198.552.840.546.853.563.975.383.191.4−35.941.848.058.269.176.684.54.0(8.6)18.50.10RCUNP500AV1■特性インバーターチラーユニット能力表■使用範囲および最小保有水量特別な改造をしないで標準仕様のまま使用できる範囲は次のとおりです。
元のページ ../index.html#13