水圧損失冷却水流量水圧損失冷却水流量水圧損失冷却水流量357912152025357912152025357912152025357912152025357912152025357912152025357912152025710121417202530710121417202530710121417202530710121417202530710121417202530710121417202530710121417202530冷水入口温度冷水出口温度冷却能力消費電力冷却能力消費電力冷却能力消費電力-水冷水冷却水出口温度冷却水入口温度-8.559.279.9811.0412.1112.5412.95-8.919.4610.0310.8010.8010.8010.80-6.426.957.488.299.089.399.7280注(1) 注(2) (℃)(℃)(℃)(℃)(kW)(kW)(m3/h)(kPa)(m3/h)(kPa)(kW)(kW)(m3/h)(kPa)(m3/h)(kPa)(kW)(kW)(m3/h)(kPa)(m3/h)(kPa)30.532.534.636.739.842.944.145.329.131.233.335.338.441.542.744.027.729.731.833.936.940.041.342.525.927.930.032.135.238.339.540.725.327.329.431.534.537.638.940.124.326.428.530.533.636.738.039.222.824.926.929.032.135.236.437.7 枠は標準仕様値を示します。 部は、冷却水流量が使用範囲外のため最大流量で記載しています(冷却水入口温度は表に記載の数値と異なります)。2010252030253530373240354540項目・単位型式出口温度℃入口温度℃冷水m3/h最大流量m3/h最小保有水量m3冷却水出口温度℃最大流量m3/h許容水圧冷側MPa冷却水側MPa注(1) 最小流量は実際に使用される冷水出口温度により異なります。( )内の値は、冷却運転の冷水出口温度を5℃未満でご使用になる場合の最小流量です。注(2) 最小保有水量は、復帰温度差2℃設定時の場合です。設定変更をした場合、必要な保有水量が変わりますのでご注意ください。最小保有水量は、圧縮機の発停頻度を基準内に収めるために必要な最低限の水量であり、水温制御を安定させるための必要水量ではありませんのでご注意ください。凝縮器60.044.750.255.965.174.778.982.955.241.446.652.260.970.574.378.450.137.842.848.256.665.969.673.644.233.738.543.551.560.464.067.942.332.337.142.050.058.762.366.039.530.334.839.847.556.159.563.2-27.231.536.143.751.855.158.79.379.9210.4710.8010.8010.8010.8010.809.189.7510.3010.8010.8010.8010.8010.809.009.5610.1110.6610.8010.8010.8010.808.729.299.8410.4110.8010.8010.8010.808.659.209.7710.3210.8010.8010.8010.808.5 9.109.6510.2210.8010.8010.8010.8031.735.138.740.840.840.840.840.830.634.037.540.840.840.840.840.829.432.936.339.940.840.840.840.827.831.234.638.240.840.840.840.827.530.734.137.740.840.840.840.826.830.033.437.040.840.840.840.8-28.932.235.840.840.840.840.861.065.169.273.379.585.788.290.758.262.466.570.676.883.085.588.055.359.463.667.773.980.182.685.051.755.960.064.170.376.579.081.550.554.658.862.969.175.377.880.248.752.856.961.167.373.575.978.445.649.753.958.064.270.472.975.33〜2533以下5.2(7.8)14.00.1020〜4510.832.836.540.543.443.443.443.443.431.435.339.143.343.443.443.443.430.133.837.841.843.443.443.443.428.332.035.839.843.443.443.443.427.931.435.339.243.443.443.443.427.230.734.538.543.443.443.443.4-29.533.237.043.243.443.443.4RCUNP300WV1水冷却器水冷圧水流損失量5.75.85.85.96.06.06.26.36.36.46.56.56.76.87.07.27.07.17.27.37.47.57.77.97.77.87.98.08.18.38.58.78.08.18.28.38.58.68.89.18.58.68.78.88.99.19.39.69.39.49.59.69.79.810.010.36.565.595.956.316.857.387.597.796.265.375.736.076.607.147.347.575.965.115.475.836.356.887.107.315.574.805.165.526.056.596.797.005.444.705.065.425.936.476.696.905.2 4.544.905.255.786.316.546.74-4.284.634.995.526.056.266.4848.135.840.244.852.159.863.066.144.133.337.541.748.756.359.262.740.330.434.438.745.352.555.758.835.627.030.935.041.448.551.354.234.126.029.833.839.946.949.952.831.624.428.131.938.144.847.950.6-21.925.329.135.041.444.147.06.236.596.957.207.207.207.207.206.096.476.857.197.207.207.207.205.976.336.717.097.207.207.207.205.786.146.526.907.207.207.207.205.736.096.476.857.207.207.207.205.6 6.026.406.767.207.207.207.20-5.906.266.647.197.207.207.20RCUNP300WV13.4(5.2)10.60.137.2RCUNP450WV1凝縮器水冷却器水冷圧水流損失量9.838.398.939.4610.2711.0611.3911.709.408.058.589.129.9110.7211.0311.358.927.678.208.749.5310.3410.6510.978.347.217.748.279.069.8710.1810.518.157.057.598.128.919.7210.0310.357.9 6.817.347.888.679.489.7910.1129.933.236.739.239.239.239.239.228.732.135.739.139.239.239.239.227.630.834.438.139.239.239.239.226.029.132.636.239.239.239.239.225.628.732.135.739.239.239.239.224.928.131.534.939.239.239.239.2-27.030.233.739.139.239.239.245.748.851.955.059.764.366.268.043.746.849.953.057.662.364.166.041.544.647.750.855.460.161.963.838.841.945.048.152.757.459.261.137.941.044.147.251.856.558.360.236.539.642.745.850.455.156.958.834.237.340.443.548.252.854.656.58.88.99.09.19.29.39.69.89.79.910.010.110.310.510.811.110.811.011.111.211.411.611.912.311.912.112.212.412.612.813.113.512.412.512.712.813.113.313.614.013.113.313.413.613.814.014.414.814.414.514.614.815.015.215.515.9RCUNP450WV10.98以下0.98以下RCUNP600WV1水冷却器水冷圧水流損失量凝縮器11.411.511.611.711.912.112.412.712.612.812.913.113.313.613.914.314.014.214.414.514.815.015.515.915.415.615.816.016.316.617.017.516.116.216.416.616.917.217.718.117.017.217.417.617.918.118.619.118.618.819.019.119.419.720.120.513.1211.2011.9012.6113.6714.7415.1715.6012.5110.7311.4412.1413.2114.2814.7115.1411.8910.2210.9411.6412.7113.7814.2114.6211.129.6110.3211.0312.0913.1613.5914.0210.869.3910.1110.8211.8912.9513.3813.7910.5 9.089.7910.5111.5812.6413.0513.4866.649.555.561.871.982.887.492.160.945.751.557.667.478.082.587.055.441.747.453.262.873.077.381.548.937.242.548.157.167.071.175.446.835.640.946.455.465.069.173.143.733.538.544.052.762.165.970.0-29.934.839.948.257.361.265.012.4513.1813.9014.4014.4014.4014.4014.4012.1812.9313.6614.4014.4014.4014.4014.4011.9212.6613.4214.1414.4014.4014.4014.4011.5412.3013.0413.7814.4014.4014.4014.4011.4612.1812.9313.6714.4014.4014.4014.4011.3 12.0412.7813.5414.4014.4014.4014.4011.7812.5413.2614.3814.4014.4014.40RCUNP600WV16.8(10.4)18.50.1314.4■特性インバーターチラーユニット能力表■使用範囲および最小保有水量特別な改造をしないで標準仕様のまま使用できる範囲は次のとおりです。
元のページ ../index.html#81