注)ï外気(凝縮器吸込空気)温度32℃・定格周波数運転(KRU-T2HV-Aは最大周波数)・冷媒配管長(水平片道)5mで無着霜の場合の値を示します。呼称出力 (kW)0.751.11.51.52.23.03.74.55.2セット型式KRU-T1HV-AKRU-T1.5HV-AKRU-T2HV-AKU-T2HV-AKU-T3HV-AKU-T4HV-AKU-T5HV-AKU-T6HV-AKU-T7HV-Aセット型式KRU-T1MHV-AKRU-T1.5MHV-AKRU-T2MHV-AKU-T2MHV-AKU-T3MHV-AKU-T4MHV-AKU-T5MHV-AKU-T6MHV-AKU-T7MHV-AKU-T8MHV-AKU-T10MHV-AKU-T12MHV-AKU-T16MHV-AKU-T20MHV-AKU-T26MHV-AKU-T30MHV-AKU-T36MHV-AKU-T40MHV-Aセット型式KRU-T1LHV-AKRU-T1.5LHV-AKRU-T2LHV-AKU-T2LHV-AKU-T3LHV-AKU-T4LHV-AKU-T5LHV-AKU-T6LHV-AKU-T8LHV-AKU-T10LHV-AKU-T12LHV-AKU-T16LHV-AKU-T20LHV-AKU-T26LHV-AKU-T30LHV-AKU-T36LHV-AKU-T40LHV-A50/60Hz(単位 : kW)庫内温度(℃)102.80/2.803.22/3.223.66/3.663.75/3.754.26/4.264.79/4.795.60/5.606.34/6.347.12/7.126.00/6.006.31/6.346.96/6.997.50/7.508.01/8.047.92/7.8711.2/11.211.7/11.712.9/12.812.5/13.213.1/13.913.7/14.314.0/15.016.6/16.918.3/18.617.0/17.018.8/18.820.7/20.7呼称出力(kW)−52.04/2.042.81/2.814.23/4.234.60/4.605.78/5.768.78/8.859.82/10.311.5/11.713.0/13.014.5/14.918.6/18.623.2/23.231.2/31.240.3/40.350.2/49.554.3/54.164.6/64.370.9/70.90.751.11.51.52.23.03.74.55.26.07.49.012.015.019.522.226.829.6呼称出力(kW)−35−−−0.751.11.51.52.23.03.74.56.07.49.012.015.019.522.026.829.61.50/1.501.85/1.832.86/2.833.22/3.173.85/3.834.93/4.815.96/5.967.88/7.8810.0/10.013.6/13.115.6/14.819.1/18.521.6/21.022.6/21.950/60Hz(単位 : kW)庫内温度(℃)101550/60Hz(単位 : kW)10153.66/3.664.79/4.797.12/7.126.96/6.997.92/7.8712.9/12.813.7/14.318.3/18.620.7/20.721.8/21.826.2/26.232.3/32.345.0/44.757.1/56.868.2/67.475.4/75.388.7/88.597.3/96.750/60Hz(単位 : kW)−10−51.65/1.652.12/2.123.45/3.453.60/3.624.57/4.596.83/6.857.57/7.619.39/9.3712.1/12.114.0/14.017.7/17.725.4/25.730.6/30.437.6/37.042.4/41.050.1/48.553.9/52.41.96/1.962.47/2.474.00/4.004.13/4.165.24/5.287.84/7.888.65/8.7110.7/10.713.7/13.815.9/15.919.8/19.828.9/29.434.3/33.843.0/42.647.3/46.156.5/55.361.1/59.716標 準 型15セット型式KU-T8HV-AKU-T10HV-AKU-T12HV-AKU-T16HV-AKU-T20HV-AKU-T26HV-AKU-T30HV-AKU-T36HV-AKU-T40HV-A2.50/2.503.35/3.355.00/5.005.30/5.306.70/6.7010.0/10.011.2/11.812.5/13.215.0/15.017.0/17.021.2/21.226.5/26.535.5/35.545.0/45.056.0/56.063.0/63.075.0/75.080.0/80.0−30−250.72/0.721.01/1.011.72/1.721.84/1.832.30/2.283.48/3.463.92/3.894.87/4.816.16/6.127.43/7.439.67/9.6712.2/12.216.9/16.419.2/18.624.2/23.027.2/26.228.3/27.00.90/0.901.23/1.232.07/2.072.22/2.222.80/2.794.19/4.184.72/4.705.99/5.967.54/7.549.06/9.0611.8/11.815.2/15.220.5/20.123.4/22.828.8/27.933.2/32.034.0/33.0呼称出力 (kW)550519.0/19.020.5/20.521.8/21.823.6/23.625.0/25.026.2/26.230.0/30.031.1/31.132.3/32.340.0/40.043.5/43.145.0/44.753.0/53.054.8/54.457.1/56.860.0/60.064.4/63.668.2/67.471.0/71.073.1/72.475.4/75.385.0/85.086.5/85.888.7/88.590.0/90.096.0/95.297.3/96.76.07.49.012.015.019.522.226.829.6庫内温度(℃)2.80/2.803.75/3.755.60/5.606.00/6.007.50/7.5011.2/11.212.5/13.214.0/15.017.0/17.019.0/19.023.6/23.630.0/30.040.0/40.053.0/53.060.0/60.071.0/71.085.0/85.090.0/90.0注)ï外気(凝縮器吸込空気)温度32℃・定格周波数運転(KRU-T2MHV-Aは最大周波数)・冷媒配管長(水平片道)5mで無着霜の場合の値を示します。3.22/3.224.26/4.266.34/6.346.31/6.348.01/8.0411.7/11.713.1/13.916.6/16.918.8/18.820.5/20.525.0/25.031.1/31.143.5/43.154.8/54.464.4/63.673.1/72.486.5/85.896.0/95.2庫内温度(℃)−20−151.12/1.121.50/1.502.50/2.502.65/2.653.35/3.355.00/5.005.60/5.607.10/7.109.00/9.0010.6/10.613.2/13.218.0/18.023.6/23.626.5/26.531.5/31.535.5/35.537.5/37.5注)ï外気(凝縮器吸込空気)温度32℃・定格周波数運転(KRU-T2LHV-Aは最大周波数)・冷媒配管長(水平片道)5mで無着霜の場合の値を示します。1.37/1.371.80/1.802.94/2.943.11/3.113.94/3.955.88/5.896.55/6.578.20/8.1910.5/10.512.4/12.415.7/15.722.0/22.027.8/27.432.6/32.038.6/37.244.8/43.347.0/45.7 ●高温用 ●中温用 ●低温用
元のページ ../index.html#17